Agenda - Advisory Design Panel Source: https://www.langleycity.ca/media/file/adp-package-december-11-2024pdf Archived copy: https://heylangley.ca/records/city-of-langley/committees/advisory-design-panel/2024/2024-12-11-agenda-adp-package-december-11-2024pdf.pdf SHA-256 of the PDF: abe3eff89719116e255c85d095cf85079a5fb7f9ae10c9e49ec30d24ac7ff66b Fetched: 2026-11-10 --- page 1 --- ADVISORY DESIGN PANEL WEDNESDAY, DECEMBER 11, 2024 AT 7:00 PM CKF Room Langley City Hall (In-Person Meeting) A G E N D A 1) AGENDA Adoption of the December 11, 2024 agenda. 2) MINUTES Adoption of minutes from the November 6, 2024 meeting. 3) PANEL MEMBERSHIP PHOTO Photo of the ADP membership for inclusion in the 2025 Volunteer Appreciation Banquet slideshow. Consent forms will be provided at the meeting. 4) DEVELOPMENT PERMIT APPLICATION DP 15-23 ZONING BYLAW AMENDMENT APPLICATION RZ 14-23 6-storey, 70-unit apartment development at 20239-20249 54A Avenue. 5) NEXT MEETING January 2025 (Panel member availability to be confirmed) 6) ADJOURNMENT --- page 2 --- Document Number: 198058 MINUTES OF THE ADVISORY DESIGN PANEL HELD IN CKF ROOM, LANGLEY CITY HALL WEDNESDAY, NOVEMBER 6, 2024 AT 7:00 PM Present: Councillor Paul Albrecht (Chair) Councillor Mike Solyom (Co-Chair) Mayor Nathan Pachal Blair Arbuthnot Jaswinder Gabri Matt Hassett Leslie Koole Dammy Ogunseitan Ritti Suvilai Absent: Tony Osborn Ella van Enter Staff: C. Johannsen, Director of Development Services K. Kenney, Corporate Officer A. Metalnikov, Planner Chair Albrecht began by acknowledging that the land on which we gather is on the traditional unceded territory of the Katzie, Kwantlen, Matsqui and Semiahmoo First Nations. 1) AGENDA Adoption of the November 6, 2024 agenda. It was MOVED and SECONDED THAT the agenda for the November 6, 2024 Advisory Design Panel be approved. CARRIED --- page 3 --- ADP Minutes – November 6, 2024 Document Number: 198058 2 2) MINUTES Adoption of minutes from the October 16, 2024 meeting. It was MOVED and SECONDED THAT the minutes of the October 16, 2024 Advisory Design Panel meeting be approved as circulated. CARRIED 3) DEVELOPMENT PER DP 06-23 BALCONY UPDATE Balcony update for a previously approved 6-storey apartment building at 19948 55A Avenue. Carl Johannsen, Director of Development Services provided information on the development permit application: • The development application had received rezoning and development permit approval and is at the building permit stage; • The applicant has requested a variance to add lumon-style glazing treatment to the patios; • This is considered a minor variance, which could be approved by the Director of Development Services; however, staff wish to ensure the Advisory Design Panel is informed of what is being proposed and is given the opportunity to provide input. The applicant team entered the meeting: • Francis Yau, Senior Architect, Andrew Cheung Architects Inc. • David Liu, Technical Drafter, Andrew Cheung Architects Inc. • Tim Chen, Owner • Jason Yang, Senior Manager - Contract & Construction, Golden Glory Development Ltd The applicant team advised that the change will enclose the balcony, permitting year round use of the space. Their PowerPoint presentation included the following: • Photos of other buildings with lumon enclosed balcony; • Enlarged balcony plan; • Renderings of current patio design and proposed enclosed balcony; • Ability to fully open panels; • North elevation comparison of building with closed and open balcony; • East elevation comparison; • West elevation comparison; • Render views - open balcony; • Render views – proposed balcony. --- page 4 --- ADP Minutes – November 6, 2024 Document Number: 198058 3 The team further advised that: • Other benefits of this change to the patio design include energy savings, extra noise buffering and greater privacy; • This style of enclosed patio has been used for many years in Europe; • The main purpose of this change is to differentiate their building from others in the same price range in order to be more competitive and attract younger buyers. In response to a question from a Panel member, staff advised that the enclosed patio is not considered additional floorspace. The applicant team responded to questions from Panel members regarding the following: • Motivation for the change in patio design; • Ability to clean the windows; • Who is responsible for maintaining and cleaning the windows; • Whether a heater could be installed in the space to allow for use as separate living space. Panel members provided feedback on the following: • Potential for owners to turn these spaces into living areas; • Strata may have issue maintaining uniform look of the building if owners use enclosed patios as living spaces. The applicant team left the meeting. In response to a question from a Panel member, staff advised this requested change to the application does not need to come to Council for approval. Further discussion ensued regarding: • Having an outlet on the patio would likely be a fire code violation; • Owners may find a way to heat these spaces even though a power outlet is not being installed on the patios. 4) DEVELOPMENT PERMIT APPLICATION DP 07-24 ZONING BYLAW AMENDMENT APPLICATION RZ 06-24 26-unit townhome development at 20815 45A Avenue & 4560-4580 208 Street. Mr. Metalnikov spoke to the staff report dated October 25, 2024 providing information on the proposed development. Staff responded to questions from Panel members regarding: • The rationale for boundaries of the multi-unit residential use designation in the OCP for this area; • Installation of traffic signal in the area; --- page 5 --- ADP Minutes – November 6, 2024 Document Number: 198058 4 • Anticipated undergrounding of power lines in the area and City requirement that developer put in conduit; • Purpose of area located at the western most corner of the development; • Feasibility of retaining tree if accessible parking space is relocated to another area; • Parking requirements for the development; • Parking analysis done to determine number of viable on-street parking spaces in the area near this development; • Intention to install curb in front of development on 208 St; • Configuration of tandem units. The Applicant team entered the meeting: Dennis Chan, Developer (Leone Homes) Fred Adab, Architect (F. Adab Architects) Azar Ahmadi, Architect (F. Adab Architects) Yiwen Ruan, Landscape Architect (PMG Landscape Architects) Mr. Adab provided a PowerPoint presentation on the proposed development, providing information on the following: • Context map; • Site Plan; • Unit Mix; • North to south rendering on 208 St.; • Elevations; • Exterior finishes and colour; • Floor plans for each building; • Building sections; • Energy saving green measures; • CPTED features. Mr. Ruan highlighted information on the landscape plan, including trees and pavers. Panel members provided feedback on the form and character of the development and discussion took place regarding the following: • Have a clearer tree map, showing trees to be retained and trees to be removed; • Ensuring the types of trees planted don’t have large roots that will break up the sidewalk as they grow; • Adding visual interest to north and south elevations of Building 3; • Potential to have a door for guest entry adjacent to garages in Building 4; • Providing more visual interest above garage doors; • Making yard space design for units in building 4 less formal; • Expanding accent paving in interior drive aisle and providing traffic calming features to protect children playing in that area, potentially through extended walkway crosswalks from Building 4; • Trade-offs between larger backyards and pedestrian walkways for Building 4; • Having doorbells on garage side of units in addition to front door side; --- page 6 --- ADP Minutes – November 6, 2024 Document Number: 198058 5 • Reviewing location of smoke alarm in kitchen to prevent false alarms; • Having front yard fencing right up to sidewalk to dissuade dog owners from having their dogs do their business in front of units; • Adding permeable pavers where possible. The applicant team responded to questions from Panel members regarding the following: • Types of trees to be planted; • View from front doors facing east; • Maximum tree height of trees on the property; • Rationale for jog in sidewalk; • Keypad entry to garages; • Different building designs in the area; • Placement of unit numbers on garage side of units; • Hiring of an acoustic consultant; • Type of fencing to be provided on the east side of the development; • Size of bed that can be accommodated in the smallest room of each unit; • Placement of balconies on the internal side in Building 2; • Developer amenity contribution for park. The applicant team left the meeting. There was further discussion on the types of trees being retained and the importance of ensuring there is enough room between these trees and trees on private property to maintain verticality of the trees. It was MOVED and SECONDED THAT: 1. The ADP receive the staff report dated October 25, 2024 for information; and 2. The ADP recommends the applicant give further consideration to the following prior to the application proceeding to Council: a. Provide a clearer tree plan (trees retained, removed, and added) b. Review the tree species used in front yards to ensure they will not impact townhome foundations c. Provide more design interest to end elevations and garage-level façades d. Consider a more creative and less formal approach to the Building 4 yards e. Expand accent paving within the internal lanes and review traffic calming measures (e.g. pathway crosswalks, elevated crosswalks/table) f. Provide unit numbers and doorbells on garage side of blocks g. Review kitchen and smoke alarm locations to prevent false alarms h. Provide front yard fencing as close to the property line as possible i. Incorporate additional permeable surfaces into the site as possible CARRIED --- page 7 --- ADP Minutes – November 6, 2024 Document Number: 198058 6 Staff notes: • Consider sidewalk design along 208 Street in terms of tree preservation and active transportation design • Seek opportunities to plant more coniferous trees, and spec columnar trees for boulevard (noting overhead wires) The Chair advised Panel members that a group photo would be taken of the Panel at the next meeting for display at the next volunteer appreciation banquet. 5) NEXT MEETING December 4, 2024 (TBC). 6) ADJOURNMENT It was MOVED and SECONDED THAT the meeting adjourn at 8:24 pm. CARRIED __________________________________ ADVISORY DESIGN PANEL CHAIR __________________________________ CORPORATE OFFICER --- page 8 --- A DVISORY D ESIGN P ANEL R EPORT To: Advisory Design Panel Subject: Development Permit Application DP 15 - 23 Rezoning Application RZ 14-23 (20239-20249 54A Avenue) File #: 6620.00 From: Anton Metalnikov, RPP, MCIP Planner Bylaw #: 3303 Doc #: Date: December 2 , 2024 RECOMMENDATION: THAT this report be received for information. 1. PROPOSAL: Development Permit and Zoning Bylaw amendment applications for a 6-storey, 70-unit apartment building at 20239-20249 54A Avenue. 2. CITY BYLAWS & POLICIES: Applying to the subject properties: a. Official Community Plan (OCP): Mid Rise Residential (6-12 storey height and maximum Floor Area Ratio of 3.5); b. Zoning: RM1 Multiple Residential Low Density; and c. Transit Oriented Area (TOA): Tier 3 (minimum allowable 8-storey height and Floor Area Ratio of 3, no residential parking requirements). The proposed development: a. Is consistent with the OCP (6-storey height and 2.7 FAR); b. Includes a rezoning to CD105 Comprehensive Development Zone to enable the proposed development in alignment with the OCP, due to the absence of a standard zone accommodating the Mid Rise Residential OCP designation in the current Zoning Bylaw; and c. Requires a Development Permit for a multi-unit residential development. --- page 9 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 2 3. DETAILED BACKGROUND INFORMATION 4. SITE CONTEXT (20239-20249 54A AVENUE) The proposed development site consists of two properties: one with a strata duplex and the other with a strata fourplex. Its surroundings include: • North: Unbuilt City lane right-of-way and Chelsea Terrace (3-storey apartment building). The development would be required to construct this lane and dedicate land to widen it to the City’s 8-metre width standard. Combined with anticipated lane construction associated with the nearby development at 20220 & 20230 Michaud Crescent (DP 14-23 and Rezoning Bylaw No. 3291; Third Reading granted September 23, 2024), this would complete the lane between Michaud Crescent and 54A Avenue. • East: Manoah Manor (3-storey apartment building). • South: 54A Avenue (local street) and Arbutus Court (3-storey apartment building). • West: Suede (4-storey apartment building). Applicant : Paramorph Architecture Inc. Owner: HOV Investments Ltd. Civic Addresses: 20239-20249 54A Avenue Legal Description: Strata Lots 1-4, District Lot 305, Group 2, New Westminster District, Strata Plan NW2626 & Strata Lots 1-2, District Lot 305, Group 2, New Westminster District, Strata Plan NW1617 Site Area: 1,863 m 2 (0.46 acres) Number of Units: 70 apartments Gross Floor Area: 4,996 m 2 (53,778 ft 2 ) Floor Area Ratio: 2.682 Lot Coverage: 49% Total Parking Required: 4 accessible spaces Parking Provided: 56 spaces (including 5 accessible spaces) OCP Designation: Mid Rise Residential Existing Zoning: RM1 Multiple Residential Low Density Proposed Zoning: CD 105 Comprehensive Development Variances Requested: N/A Estimated Development Cost Charges (DCCs): $1,235,928.00 (City - $573,600.00, GVS&DD - $264,762.00, GVWD - $262,102.00, SD35 - $36,400.00, TransLink - $99,064.00) Community Amenity Contributions (CACs): $284,400.00 --- page 10 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 3 Key neighbourhood amenities within walking distance include: • Linwood Park (few minutes’ walk); • Timms Community Centre (5-to-10-minute walk); and • Nicomekl Elementary School (10-minute walk). Nearby transportation services include: • Six local and regional bus routes within a 5-minute walk; • The frequent 503 Fraser Highway Express bus (5 to 10-minute walk); and • The planned Langley City Centre SkyTrain station and its associated transit exchange (5 to 10-minute walk). Context map 5. Proposed Site and Building Design A. Site Layout and Building Massing The proposed development is for a wood-frame building, with a flat roof, in a rectangular shape oriented north-south. A single level of underground parking is provided, with additional surface parking provided on the rear half of the site. The building’s ground floor screens this parking area from the lone street frontage and upper floors extend their footprint over it on Subject Site 6 - storey apartment building in application Arbutus Court Manoah Manor 6-storey apartment building U/C 8-storey apartment building U/C 6-storey apartment building U/C 6-storey apartment building in application Mixed-use multi-phase development Chelsea Terrace Suede Linwood Park --- page 11 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 4 columns. Pedestrian access is provided to both 54A Avenue to the south, with the main entrance on the building’s corner, and the lane to the north, while vehicle access is limited to the rear lane. B. Building Elevations and Materials The parkade extrudes slightly above grade and is clad with brick veneer. This brick extends up the first two floors of the building. Elsewhere, the cladding consists primarily of grey and wood-tone fiber cement panelling. Both glass and black picket aluminum balcony railings are used. Cantilevered balconies and extruded masses, frames, and cornices add depth to the façades. C. Landscaping Landscaping consists of a planted perimeter and a programmed rooftop amenity deck. Plantings include a variety of shrubs and ground covers, along with 6 trees proposed on-site, with additional street trees to be provided as part of required frontage upgrades. Solid black aluminum fencing is provided on the side property lines and between the ground floor patios. The rooftop deck hosts dining and lounge areas and 15 garden plots, with linear planters with Japanese Holly plants delineating these different spaces. This rooftop area is set back from the roof edges for safety and privacy. D. Building Program and Details The building’s unit mix includes: • 13 studios (19%); • 31 one-bedroom units (44%); • 21 two-bedroom units (30%); and • 5 three-bedroom units (7%). 15 (21%) of the units are adaptable. Resident storage facilities are provided in storage rooms in the underground parkade as well as within in-unit storage rooms. 514 m 2 (5,522 ft 2 ) or total amenity space is provided, including 215 m 2 (2,309 ft 2 ) of indoor space and 299 m 2 (3,213 ft 2 ) of outdoor space split between the rooftop deck and a ground-floor patio outside the indoor amenity lounge. 6. Sustainability Features • Construction techniques that minimize site disturbance and protect air quality; --- page 12 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 5 • Lighting systems meeting ground-level and dark skies light pollution reduction principles; • Incorporating a construction recycling plan; • Reduced heat island effect with a high-reflectivity roof; • Non-water dependent and drought-tolerant materials in the landscape design served by an irrigation system with central control and rain sensors; • Water-conserving toilets; • 8 resident parking stalls with Level II electric vehicle (EV) chargers; and • 15 resident garden plots. 7. CPTED The applicant’s proposal benefited from a comprehensive Crime Prevention Through Environmental Design (CPTED) review by a qualified consultant whose recommendations were incorporated into the plans. 8. Variances No variances are required for this application. Under recent Provincial legislation the City cannot require a specific number of residential and residential visitor parking spaces at this location (Transit Oriented Area, TOA). 9. Engineering Additional design changes may be required upon further investigation, site inspections and receipt of other supporting reports and documents. All work to be done to the City of Langley’s Design Criteria Manual (DCM), and the City’s Subdivision and Development Servicing Bylaw (SDSB). Per the City’s DCM requirement, the developer and their consulting engineer shall submit to the City Engineer a signed and sealed copy of Form F-1 (Commitment by Owner and Consulting Engineer) prior to starting their design works. Per the City’s Watercourse Protection Bylaw No. 3152, the developer’s consulting engineer shall submit to the City Engineer a signed and sealed copy of Form F-1 (Confirmation of Commitment by Qualified Environmental Professional - QEP) prior to starting their site monitoring works. These requirements have been issued to reflect the application for a proposed 70-Unit Apartment Development located at 20239-20249 54A Avenue . --- page 13 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 6 These requirements may be subject to change upon receipt of a development application . The City’s Zoning Bylaw, 1996, #2100 has requirements concerning landscaping for buffer zonings, parking and loading areas, and garbage and recycling containers, all of which applies to this design. A) The developer is responsible for the following work which shall be designed by a Professional Engineer: I. A Qualified Environmental Professional (QEP) must be engaged to imple- ment erosion and sediment control in accordance with the City of Langley Watercourse Protection Bylaw #3152, as amended. II. A storm water management plan for the site is required. Rainwater man- agement measures used on site shall limit the release rate to pre-develop- ment levels to mitigate flooding and environmental impacts as detailed in the City’s DCM. All calculations shall be based the City’ DCM with 20% added to the calculated results to account for climate change. A safety fac- tor of 20% shall be added to the calculated storage volume. Pre-develop- ment release rates shall not include climate change effect. III. All existing services shall be capped at the main by the City, at the Devel- oper’s expense prior to applying for a demolition permit. IV. New water, sanitary and storm sewer service connections are required. All pertinent pipe design calculations shall be submitted in spreadsheet format and shall include all formulas for review by the City. The Developer’s engi- neer will determine the appropriate main tie-in locations and size the con- nections for the necessary capacity. V. At the Developer’s expense, the capacity of the existing water and sanitary sewer mains shall be assessed through hydraulic modeling performed by the City’s standing hydraulic modeling consultant per DCM 3.8 and 6.5. a. Any upgrade requirement for either sanitary or water mains not cov- ered under the City’s DCC bylaw shall be designed and installed by the Developer at the Developer’s expense. b. At the Developer’s expense, the City’s standing hydraulic modeling consultant shall conduct a fire hydrant flow test to be used in the City’s water modeling to determine if the existing water network is adequate for fire flows (based on architectural data supplied by the Developer’s Architect). Upgrading of the existing watermain(s) may be necessary to achieve the necessary pressure and flows to conform to Fire Under- writers Survey (FUS) “Water Supply for a Public Fire Protection, a Guide to Recommended Practice, 1995.” VI. Additional C71P fire hydrants may be required to meet bylaw and firefighting requirements. Hydrant locations must be per DCM Section 3.10 and ap- proved by the City Engineer and the City of Langley Fire Rescue Service. --- page 14 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 7 VII. A property dedication of approximately 2m will be required along the lane frontage north of the proposed development to achieve a 8m right of way width. VIII. At the Developer's expense, a Traffic Impact Assessment (TIA) will be com- pleted per the DCM Section 8.21. The proposed development plan and sta- tistics, once ready, should be forwarded to the City Engineer to develop the scope of this traffic study.TIA reports must be approved by the City Engineer prior to taking the application to Council. The TIA completion timing must be: a. For OCP Amendment / Rezoning Applications: Prior to Council’s first and second readings; and b. For Development Permits (DP): Prior to Council consideration of the application. IX. The scope and extent of the off-site works be determined in part from the TIA. New sidewalk, barrier curb, gutter will be required along the entire 54A St. frontage, complete with boulevard trees and a planting strip as per the City DCM cross-section SS-R07 and Section 11.0 - Specifications and Standards for Landscaping. X. The condition of the existing pavement along the proposed project’s frontages shall be assessed by a geotechnical engineer. Pavements shall be adequate for an expected road life of 20 years under the expected traffic conditions for the class of road. Road construction and asphalt overlay de- signs shall be based on the analysis of the results of Benkelman Beam tests and test holes carried out on the existing road which is to be upgraded. If the pavement is inadequate, it shall be remediated by the Developer, at the Developer’s expense. XI. The site layout shall be reviewed by a qualified Professional Engineer to ensure that the parking layout, vehicle circulation, turning paths and access design meet applicable standards and sightline requirements, including set- backs from property lines. Appropriate turning templates should be used to prove parking stalls, loading areas and drive aisles are accessible by ser- vice vehicles. Refer to DCM Section 8. The design shall be adequate for MSU trucks as the design vehicle. XII. Existing street lighting along the entire project frontage shall be analyzed (excluding any BC Hydro lease lights) by a qualified electrical consultant to ensure street lighting and lighting levels meet the criteria outlined in DCM 9.0. Any required street lighting upgrades, relocation, and/or replacement shall be done by the Developer at the Developer’s expense. Any existing BC Hydro lease-lights to be removed and disposed of off-site. XIII. Eliminate the existing overhead BC Hydro/telecommunication infrastructure along the development’s 54A Avenue project frontage by replacing with un- derground infrastructure. XIV. A dedicated on-site loading zone shall be provided by the developer. The design shall be adequate for MSU trucks as the design vehicle. --- page 15 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 8 B) The Developer is required to deposit the following bonding and fees: I. The City will require a Security Deposit based on the estimated construction costs of installing civil works, as approved by the City Engineer. II. The City will require inspection and administration fees in accordance to the Subdivision Bylaw based on a percentage of the estimated construction costs, as per the City’s Subdivision and Development Servicing Bylaw 2021 #3126. III. A deposit for a storm, sanitary and water services is required, which will be determined by City staff after detailed civil engineering drawings are sub- mitted, sealed by a Professional Engineer. IV. The City will require a $40,000 bond for the installation of a water meter to current City standards as per the DCM. V. A signed and sealed pavement cut form (Form F-2 of the City’s DCM) shall be completed by the developer’s consulting engineer. Upon the review and approval of the City Engineer of the submitted form, the corresponding Per- manent pavement cut reinstatement and degradation fees shall be paid by the Developer. NOTE: Deposits for utility services or connections are estimates only. The actual cost incurred for the work will be charged. The City will provide the developer with an estimate of connections costs, and the Developer will declare in writing that the estimate is acceptable. C) The Developer is required to adhere to the following conditions: I. The Developer’s Consulting Engineer shall perform their periodic Field Re- views, As required by EGBC, and send a copy of the Review to the City Engineer within a week of completion of each Review II. Unless otherwise specified by the City Engineer, all engineering works shall be designed based on the City’s DCM specifications in accordance with the City’s Subdivision and Development Servicing Bylaw 2021, No. 3126 III. Undergrounding of hydro, telecommunication to the development site is re- quired, complete with underground or at-grade transformer IV. Transformers servicing developments are to be located on private property with maintenance access located on private property. All transformers to be wrapped upon installation by the Developer. V. All survey costs and registration of documents with the Land Titles Office are the responsibility of the developer/owner. Please refer to the City’s Sub- division and Development Servicing Bylaw 2021, No. 3126 for more details. VI. A water meter is required to be installed on private property, preferably in the mechanical room, in accordance to the City's DCM standards at the Developer's cost. --- page 16 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 9 VII. An approved backflow prevention assembly must be installed on the do- mestic water connection immediately upon entering the building to provide premise isolation. VIII. A Stormceptor or equivalent oil separator is required to treat site surface drainage. IX. A complete set of record drawings (as-built) of off-site works, service record cards and a completed tangible capital asset form (TCA) all sealed by a Professional Engineer shall be submitted to the City within 60 days of the substantial completion date. Digital drawing files in .pdf and .dwg formats shall also be submitted. All the drawing submissions shall: a. Use City’s General Note Sheet and Title Block; and b. Closely follow the format and sequence outlined in the City’s DCM that will be provided to the Developer’s Consulting Engineer. X. The selection, location and spacing of street trees and landscaping are sub- ject to the approval of the City Engineer. Please refer to the City’s DCM for more details. XI. Stormwater run-off generated on the site shall not impact adjacent proper- ties, or roadways. XII. Garbage and recycling enclosures shall accommodate on the site and be designed to meet Metro Vancouver’s “Technical Specifications for Recy- cling and Garbage Amenities in Multi-family and Commercial Developments - June 2015 Update.” Please refer to the City’s Subdivision and Develop- ment Servicing Bylaw 2021, No. 3126 for more details. 10. Fire Department Comments Fire department access for the whole project was reviewed to ensure adequate access was in place for apparatus and firefighters. A construction fire safety plan shall be completed, complete with crane inspection records. A progressive standpipe installation will be required as construction rises. Standpipes will be required at the main entrance of the parkade, at the stairwells on rooftop, and in elevator lobbies. Stairwells act as an area of refuge and should be made as wide as possible (60”) All garbage/recycling containers must be stored in a fire rated, sprinklered room, and must be of adequate size to prevent spillover into adjacent area. Marked Exits must not be on a fob. A radio amplification bylaw is currently in development and will need to he adhered to. Consideration will be given to the installation of power banks in the storage room lockers for e- bikes charging. A Fire Safety plan and FD lock box (Knox box) will be required before occupancy. The 4” FDC will be located on a pedestal at the front of the building, exact location to be discussed with the Fire Department at a later date. --- page 17 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 10 11. Budget Implications In accordance with Development Cost Charges Bylaw, 2024, No. 3256 and the City’s Amenity Contributions Policy, the proposed development is estimated to contribute the following to the City: • Development Cost Charges (DCCs): $573,600.00 • Community Amenity Contributions (CACs): $284,400.00 Prepared by: _______________________ Anton Metalnikov, RPP, MCIP Planner Concurrence: Concurrence: __________________________ _______________________ Roy M. Beddow, RPP, MCIP Carl Johannsen, RPP, MCIP Deputy Director of Development Services Director of Development Services Concurrence: Concurrence: __________________________ __________________________ Rachel Ollenberger, AScT Scott Kennedy, Fire Chief Manager of Engineering Services Attachments --- page 18 --- To: Advisory Design Panel Date: December 2, 2024 Subject: Development Permit Application DP 15-23 & Rezoning Application RZ 14-23 Page 11 DEVELOPMENT PERMIT APPLICATION DP 15-23 REZONING APPLICATION RZ 14-23 Civic Addresses: 20239-20249 54A Avenue Legal Description: Strata Lots 1-4, District Lot 305, Group 2, New Westminster District, Strata Plan NW2626 & Strata Lots 1-2, District Lot 305, Group 2, New Westminster District, Strata Plan NW1617 Applicant: Paramorph Architecture Inc. Owner: HOV Investments Ltd. --- page 19 --- MULTI FAMILY DEVELOPMENT 20239 & 20247, 54A Avenue, Langley City, British Columbia DEVELOPMENT PERMIT APPLICATION --- page 20 --- 54A Avenue LANE MICHAUD CRESCENT 203 ST 201A ST 54 AVENUE SUBJECT LOT LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-0.2 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PROJECT SUMMARY DRAWING LIST COVER PAGE A-0.1 LOCATION MAP AND TEAM A-0.2 LAND USE & CONCEPT PLAN A-0.3 CONTEXT PLAN A-0.4 PROGRAM SUMMARY A-0.5 BASE PLAN A-0.6 SHADOW STUDY A-0.7 SITE PLAN A-1.0 FLOOR PLANS A-2.0 TO A-2.7 PERSPECTIVES A-3.0 TO A-3.7 MATERIAL BOARD A-3.8 ELEVATIONS A-3.9 TO A-3.10 SECTIONS A-4.0 TO A-4.1 UNIT PLANS A-5.0 TO A-5.6 GARBAGE ENCLOSURE DETAIL A-6.0 MAILBOX ROOM DETAIL A-6.1 LOCATION PROJECT TEAM ARCHITECT - PARAMORPH ARCHITECTURE INC. 308-9639 137A Street Surrey,BC V3T0M1 (604) 608-0161 info@paramorph.com SURVEYOR - TARGET LAND SURVEYING Surrey, BC (604) 583-6161 LANDSCAPE - DAVID STOYKO LANDSCAPE ARCHITECT 2686 6th Avenue East Vancouver, BC V5M 1R3 (604) 720-0048 david@davidstyko.com CIVIL - CENTRAS ENGINEERING LTD. 218 - 2630 Croydon Drive Surrey, BC V3S 6T3 (778)879-7602 aman@centras.ca ARBORIST - FROGGERS CREEK TREE CONSULTANTS LTD. 7763 McGregor Avenue Burnaby, BC V5J 4H4 (604)721-6002 glenn@froggerscreek.ca CPTED - LIAHONA SECURITY CONSORTIUM INC. (250)418-0770 liahonasecurity@shaw.ca GEOTECH - GEOPACIFIC CONSULTANTS 1779 West 75th Avenue Vancouver, BC V6P 6P2 (604)439-0922 N --- page 21 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-0.3 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N.T.S. LAND USE AND CONCEPT PLAN LANGLEY CITY - LAND USE CONCEPT PLAN PARKS AND OPEN SPACE CONCEPT PLAN ACTIVE TRANSPORTATION CONCEPT - ROAD NETWORK FUTURE TRANSPORTATION CONCEPT - ROAD NETWORK LEGEND FOR LAND USE CONCEPT PLAN LEGEND FOR TRANSPORTATION CONCEPT-ROAD NETWORK FUTURE ACTIVE TRANSIT-ORIENTED RESIDENTIAL TRANSIT-ORIENTED CORE TRANSIT-ORIENTED RESIDENTIAL TRANSIT-ORIENTED RESIDENTIAL PARKS AND OPEN SPACE MID RISE RESIDENTIAL MID RISE RESIDENTIAL MID RISE RESIDENTIAL LOW RISE RESIDENTIAL LOW RISE RESIDENTIAL LOW RISE RESIDENTIAL LOW RISE RESIDENTIAL PARKS AND OPEN SPACE PARKS AND OPEN SPACE LOW RISE RESIDENTIAL LOW RISE RESIDENTIAL LOW RISE RESIDENTIAL LOW RISE RESIDENTIAL MID RISE RESIDENTIAL MID RISE RESIDENTIAL MID RISE RESIDENTIAL MID RISE RESIDENTIAL 54A AVENUE LANE 54 AVENUE 53A AVENUE 203 STREET 204 STREET 201 STREET TRANSIT-ORIENTED RESIDENTIAL PARKS AND OPEN SPACE PARKS AND OPEN SPACE SUBJECT LOT PROPOSED 6 STOREY MULTIFAMILY RESIDENTIAL TRANSIT-ORIENTED RESIDENTIAL MID RISE RESIDENTIAL 53 AVENUE MICHAUD CRES N --- page 22 --- MULTI-FAMILY APARTMENTS MULTI-FAMILY APARTMENTS LANE 54 AVENUE LANE FUTURE 6-STOREY MULTI-FAMILY RESIDENTIAL 54A AVENUE 203 STREET MICHAUD CRESCENT 201A STREET LINWOOD PARK LANE MULTI-FAMILY APARTMENTS MULTI-FAMILY APARTMENTS MULTI-FAMILY APARTMENTS MULTI-FAMILY APARTMENTS TOWNHOUSE DEVELOPMENT MULTI-FAMILY APARTMENTS SINGLE FAMILY DEVELOPMENT TOWNHOUSE DEVELOPMENT TOWNHOUSE DEVELOPMENT FUTURE 6-STOREY MULTI-FAMILY RESIDENTIAL SUBJECT LOT PROPOSED 6-STOREY MULTI-FAMILY RESIDENTIAL LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-0.4 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N CONTEXT PLAN N.T.S. --- page 23 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-0.5 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PROGRAM SUMMARY Program Summary --- page 24 --- 169'-11 3 4 " [51.81M.] 163'-9" [49.91M.] 170'-1 1 4 " [51.85M.] 163'-10 1 2 " [49.95M.] 117'-11 1 4 " [35.95M.] 19'-7" [5.97M.] 78'-6 1 2 " [23.94M.] 19'-9 1 4 " [6.03M.] 118'-0" [35.97M.] 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 2 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 9'-10" [3.00M.] SETBACK 6'-2 3 4 " [1.90M.] 6'-2 3 4 " [1.90M.] SUBJECT LOT 54 A AVENUE LANE NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE EX PROPERTY LINE EX PROPERTY LINE SETBACK LINE SETBACK LINE SETBACK LINE NEW PROPERTY LINE PROPERTY LINE SETBACK LINE 1.90m DEDICATION POTENTIAL LOCATION OF DETENTION TANK LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-0.6 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N BASE PLAN --- page 25 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-0.7 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N SHADOW STUDY 1 SHADOW @ EQUINOX MARCH 20 9AM 2 SHADOW @ EQUINOX MARCH 20 12NOON SHADOW @ EQUINOX SEP 20 9AM SHADOW @ EQUINOX SEP 20 12NOON SHADOW @ EQUINOX SEP 20 3PM 3 SHADOW @ EQUINOX MARCH 20 3PM SUBJECT LOT 54A AVENUE 54A AVENUE 54A AVENUE SUBJECT LOT SUBJECT LOT SUBJECT LOT 54A AVENUE 54A AVENUE 54A AVENUE SUBJECT LOT SUBJECT LOT N.T.S. --- page 26 --- UP DN UP DN LOCK BOX (KNOX BOX) STAND ALONE FDC RAMP DN TO PARKADE @14% SLOPE V1 SC V2 SC V3 SC V4 SC LOADING BAY V5 V6 PATIO PATIO PATIO V7 V8 V9 V10 V11 V12 GARBAGE ROOM VEHICULAR ENTRANCE EX PROPERTY LINE NEW PROPERTY LINE VEST. 1.5m WIDE HALLWAY 1.5m WIDE HALLWAY MAIL ROOM SC UNIT-C UNIT-A UNIT-B UNIT-C2 LOUNGE RESIDENTIAL LOBBY VEST. POTENTIAL LOCATION FOR DETENTION TANK RAMP UP @8.10% SLOPE PARKADE LINE BELOW 9'-10" [3.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK STAIR-A STAIR-B ELEV. 93'-3" [28.42M.] 10'-8" [3.25M.] 59'-9 3 4 " [18.23M.] 6'-2 3 4 " [1.90M.] BICYCLE PARKING #3 6.1m WIDE DRIVE AISLE PROPERTY LINE BICYCLE PARKING #3 163'-10 1 2 " [49.95M.] 18'-6 1 4 " [5.64M.] 163'-9" [49.91M.] 68'-9 1 2 " [20.97M.] 23'-11" [7.29M.] 117'-11" [35.94M.] LINE OF FLOOR ABOVE 57'-9" [17.60M.] 20'-8" [6.30M.] 19'-11 1 2 " [6.08M.] 19'-7 3 4 " [5.99M.] 118'-0 1 4 " [35.97M.] 1.90m ROAD DEDICATION EXIT UP UP UP RAMP UP @5% SLOPE MAIN ENTRANCE 25'-2 1 2 " [7.68M.] UNIT-C1 PATIO 19'-8 1 4 " [6.00M.] SETBACK 23'-7" [7.19M.] 19'-8" [6.00M.] (2BR) (STUDIO) (STUDIO) (STUDIO) (1BR+DEN) 102'-1" [31.12M.] 54 A AVENUE LANE NEIGHBOURING LOT PMT NEIGHBOURING LOT M.F.E =10.75m 3.75% SLOPE 10.25 10.22 10.60 10.60 10.22 10.10 10.70 10.20 10.22 10.60 10.60 10.10 10.70 10.60 EXIT 10.15 A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 PARKADE LINE BELOW V13 V14 SC SC OUTDOOR AMENITY (84 SQM) INDOOR AMENITY PART B (94 SQM) PATIO INDOOR AMENITY PART A (121 SQM) LOUNGE STAND ALONE FDC 10.60 10.60 10.60 BIKE MAINTENANCE AREA GYM MANAGER'S OFFICE ANNUNCIATOR PANEL 3% SLOPE 10.73 PROPERTY LINE PROPERTY LINE LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-1.0 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N SITE PLAN 1/16" = 1'-0" --- page 27 --- UP UP STAIR-B ELEV. VEST. VEST. DOOR WITH VISION PANEL DOOR WITH VISION PANEL DOOR WITH VISION PANEL 1 SC 2 SC 3 SC 4 SC 5 SC 6 BICYCLE PARKING (#19) STORAGE LOCKER (#6) MECH. ROOM ELEC. ROOM PMT ABOVE POTENTIAL LOCATION FOR DETENTION TANK 7 8 9 10 11 12 13 14 15 16 17 18 19 21 22 23 24 25 26 27 29 30 31 32 33 38 39 40 6.1m WIDE DRIVE AISLE 6.1m WIDE DRIVE AISLE 6.1m WIDE DRIVE AISLE 6.1m WIDE DRIVE AISLE EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV EV 8'-2 1 4 " [2.50M.] 16'-0 3 4 " [4.90M.] 4'-11" [1.50M.] 7'-10 1 2 " [2.40M.] 12'-9 1 2 " [3.90M.] 8'-6 1 4 " [2.60M.] 18'-0 1 2 " [5.50M.] SC ACCESSIBLE STALL SMALL CAR STALL REGULAR STALL 19'-0 1 2 " [5.80M.] LANE NEW PROPERTY LINE EX PROPERTY LINE 3'-11 1 2 " [1.21M.] 8'-9" [2.67M.] 102'-10 3 4 " [31.36M.] 2'-3 1 2 " [0.70M.] 3'-9 1 4 " [1.15M.] 126'-0 1 2 " [38.42M.] 30'-6 1 2 " [9.31M.] 3'-4 3 4 " [1.03M.] 147'-7 3 4 " [45.00M.] 9'-0 1 4 " [2.75M.] 3'-3 1 2 " [1.00M.] 3'-10 3 4 " [1.19M.] 54 A AVENUE PROPERTY LINE 94'-9 1 2 " [28.90M.] 17'-5 1 2 " [5.32M.] 2'-3 1 2 " [0.70M.] 3'-3 1 2 " [1.01M.] NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE PROPERTY LINE RAMP UP TO GRADE LVL @14% SLOPE 1.90m ROAD DEDICATION 20 28 34 41 42 7.42 GRADE LVL @2.15% SLOPE 7.42 7.14 EV-2 EV-2 EV-2 EV-2 EV-2 EV-2 EV-2 EV-2 A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A 37 SC EV EV 35 EV 36 LINE OF BUILDING ABOVE LINE OF BUILDING ABOVE LINE OF RAMP ABOVE 2'-0" [0.61M.] 2'-0" [0.61M.] 4'-1 3 4 " [1.26M.] 2'-0" [0.61M.] 20'-0" [6.10M.] 20'-0" [6.10M.] 20'-0" [6.10M.] 2'-0" [0.61M.] 2'-0" [0.61M.] 2'-0" [0.61M.] 2'-0" [0.61M.] 2'-0" [0.61M.] BICYCLE PARKING (#16) STORAGE LOCKER (#7) HORIZONTAL BICYCLE PARKING HORIZONTAL BICYCLE PARKING VERTICAL BICYCLE PARKING (#7) 363 CU.FT 363 CU.FT 363 CU.FT 363 CU.FT 396 CU.FT 459 CU.FT 279 CU.FT 226 CU.FT 226 CU.FT 226 CU.FT 226 CU.FT 226 CU.FT 322 CU.FT LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.0 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PARKADE LVL-1 N 1/16" = 1'-0" --- page 28 --- UP DN UP DN INDOOR AMENITY ( 121 SQM) EX PROPERTY LINE NEW PROPERTY LINE VEST. 1.5m WIDE HALLWAY 1.5m WIDE HALLWAY MAIL ROOM UNIT-C UNIT-A1 UNIT-B RESIDENTIAL LOBBY VEST. 9'-10" [3.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK STAIR-A STAIR-B ELEV. 66'-4 1 4 " [20.22M.] 10'-3" [3.12M.] 60'-1" [18.31M.] 6'-2 3 4 " [1.90M.] PROPERTY LINE 163'-10 1 2 " [49.95M.] 18'-1" [5.51M.] 163'-9" [49.91M.] 68'-7 1 2 " [20.92M.] 23'-11" [7.29M.] 117'-11" [35.94M.] 57'-9" [17.60M.] 20'-8" [6.30M.] 19'-11 1 2 " [6.08M.] 19'-7 3 4 " [5.99M.] 118'-0 1 4 " [35.97M.] 1.90m ROAD DEDICATION 19'-8 1 4 " [6.00M.] SETBACK 23'-2" [7.06M.] 20'-1" [6.12M.] EXIT MAIN ENTRANCE 25'-4 1 2 " [7.74M.] UNIT-C1 (2BR- 789 sqft) #107 (STUDIO 512sqft) #109 (1BR + DEN - 534 sqft) #106 102'-6 1 4 " [31.25M.] 54 A AVENUE LANE NEIGHBOURING LOT NEIGHBOURING LOT M.F.E =10.70m EXIT VEHICULAR ENTRY VISITOR PARKING VISITOR PARKING 6.1m WIDE DRIVE AISLE RAMP DN TO PARKADE @14% SLOPE REFER LANDSCAPE FOR DETAIL 27'-1" [8.25M.] 24'-11 1 2 " [7.60M.] GYM/YOGA #103 LOUNGE #102 A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 MANAGER'S OFFICE #104 UNIT-C2 (STUDIO-573 sqft) #105 VEST. INDOOR AMENITY (94 SQM) BIKE MAINTENANCE AREA PROPERTY LINE PROPERTY LINE LOUNGE #101 (STUDIO 501sqft) #108 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.1 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 MAIN FLOOR PLAN N 1/16" = 1'-0" --- page 29 --- UP DN UP DN LANE NEW PROPERTY LINE EX PROPERTY LINE PROPERTY LINE NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE PROPERTY LINE 54 A AVENUE 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 1.5M WIDE HALLWAY STAIR-B 19'-8 1 4 " [6.00M.] SETBACK 9'-10" [3.00M.] SETBACK 169'-11 3 4 " [51.81M.] 163'-10 1 2 " [49.95M.] 118'-0" [35.97M.] ELEV. BAL. (PARKING BELOW) (RAMP BELOW) 1.90m ROAD DEDICATION 78'-5" [23.90M.] 19'-11" [6.07M.] 19'-8 1 4 " [6.00M.] BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. 78'-5" [23.90M.] 19'-8 1 4 " [6.00M.] 117'-11" [35.94M.] 19'-9 3 4 " [6.04M.] A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A UNIT-B UNIT-D UNIT-C UNIT-E UNIT-F UNIT-G UNIT-H UNIT-J (STUDIO - 512sqft) #202 (ADAP.) (1BR - 537 sqft) #201 (2BR- 666 sqft) #209 (3 BR - 853 sqft) #203 (1BR - 432 sqft) #204 (1BR - 634 sqft) #205 (ADAP.) (1BR - 689 sqft) #206 UNIT-A 5'-11" [1.81M.] BAL. (2BR- 789 sqft) #211 (1BR - 491 sqft) #210 UNIT-K UNIT-K1 (2 BR - 885 sqft) #212 (2 BR - 797 sqft) #208 UNIT-C (STUDIO - 512sqft) #213 19'-8 1 4 " [6.00M.] 20'-0" [6.10M.] 10'-6 1 2 " [3.22M.] 25'-0 3 4 " [7.64M.] 10'-3" [3.12M.] 25'-0 3 4 " [7.64M.] 49'-4 1 4 " [15.04M.] 29'-7 1 2 " [9.03M.] 29'-4" [8.94M.] 50'-5 3 4 " [15.39M.] 31'-3 1 4 " [9.53M.] 27'-1" [8.26M.] UNIT-H (ADAP.) (1BR - 689 sqft) #207 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.2 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 SECOND FLOOR PLAN N 1/16" = 1'-0" --- page 30 --- UP DN UP DN LANE NEW PROPERTY LINE EX PROPERTY LINE PROPERTY LINE NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE PROPERTY LINE 54 A AVENUE 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 1.5M WIDE HALLWAY STAIR-B 9'-10" [3.00M.] SETBACK ELEV. 1.90m ROAD DEDICATION BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A UNIT-B UNIT-D UNIT-C UNIT-E UNIT-F UNIT-G UNIT-H UNIT-J (STUDIO - 512sqft) #302 (ADAP.) (1BR - 537 sqft) #301 (2BR- 666 sqft) #309 (3 BR - 853.23 sqft) #303 (1BR - 634 sqft) #305 UNIT-A (2BR- 789 sqft) #311 (1BR - 491 sqft) #310 (1BR - 432 sqft) #304 (ADAP.) (1BR - 688 sqft) #306 19'-8 1 4 " [6.00M.] SETBACK 169'-11 3 4 " [51.81M.] 163'-10 1 2 " [49.95M.] 118'-0" [35.97M.] 78'-5" [23.90M.] 19'-11" [6.07M.] 19'-8 1 4 " [6.00M.] 78'-5" [23.90M.] 19'-8 1 4 " [6.00M.] 117'-11" [35.94M.] 19'-9 3 4 " [6.04M.] UNIT-K UNIT-K1 (2 BR - 885 sqft) #312 (2 BR - 796 sqft) #308 UNIT-C (STUDIO - 512 sqft) #313 BAL. 19'-8 1 4 " [6.00M.] 20'-0" [6.10M.] 10'-6 1 2 " [3.22M.] 25'-0 3 4 " [7.64M.] 10'-3" [3.12M.] 25'-0 3 4 " [7.64M.] 49'-4 1 4 " [15.04M.] 29'-7 1 2 " [9.03M.] 29'-4" [8.94M.] 50'-5 3 4 " [15.39M.] 31'-3 1 4 " [9.53M.] 27'-1" [8.26M.] UNIT-H (ADAP.) (1BR - 688 sqft) #307 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.3 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N THIRD FLOOR PLAN 1/16" = 1'-0" --- page 31 --- UP DN UP DN BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. 1.5M WIDE HALLWAY STAIR-B ELEV. LANE NEW PROPERTY LINE EX PROPERTY LINE PROPERTY LINE NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE PROPERTY LINE 54 A AVENUE 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 9'-10" [3.00M.] SETBACK 1.90m ROAD DEDICATION A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A 5'-11" [1.81M.] UNIT-B UNIT-D UNIT-C UNIT-E UNIT-F UNIT-G UNIT-H UNIT-J (STUDIO - 512sqft) #402 (ADAP.) (1BR - 537 sqft) #401 2BR- 666 sqft) #409 (3 BR - 853 sqft) #403 (1BR - 634 sqft) #405 UNIT-A (2BR- 789sqft) #411 (1BR - 491 sqft) #410 (1BR - 432 sqft) #404 (ADAP.) (1BR - 689 sqft) #406 19'-8 1 4 " [6.00M.] SETBACK 169'-11 3 4 " [51.81M.] 163'-10 1 2 " [49.95M.] 118'-0" [35.97M.] 78'-5" [23.90M.] 19'-11" [6.07M.] 19'-8 1 4 " [6.00M.] 78'-5" [23.90M.] 19'-8 1 4 " [6.00M.] 117'-11" [35.94M.] 19'-9 3 4 " [6.04M.] UNIT-K UNIT-K1 (2 BR - 885sqft) #412 (2 BR 797 sqft) #408 UNIT-C (STUDIO - 512sqft) #413 BAL. 19'-8 1 4 " [6.00M.] 20'-0" [6.10M.] 10'-6 1 2 " [3.22M.] 25'-0 3 4 " [7.64M.] 10'-3" [3.12M.] 25'-0 3 4 " [7.64M.] 49'-4 1 2 " [15.05M.] 29'-7 1 2 " [9.03M.] 29'-4" [8.94M.] 50'-5 3 4 " [15.39M.] 31'-3 1 4 " [9.53M.] 27'-1" [8.26M.] UNIT-H (ADAP.) (1BR - 689 sqft) #407 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.4 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N FOURTH FLOOR PLAN 1/16" = 1'-0" --- page 32 --- UP DN UP DN BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. 1.5M WIDE HALLWAY STAIR-B ELEV. LANE NEW PROPERTY LINE EX PROPERTY LINE PROPERTY LINE NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE PROPERTY LINE 54 A AVENUE 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 9'-10" [3.00M.] SETBACK 1.90m ROAD DEDICATION A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A BAL. 5'-11" [1.81M.] 19'-8 1 4 " [6.00M.] 19'-8 1 4 " [6.00M.] SETBACK 20'-0" [6.10M.] 10'-6 1 2 " [3.22M.] 169'-11 3 4 " [51.81M.] 163'-10 1 2 " [49.95M.] 118'-0" [35.97M.] 25'-0 3 4 " [7.64M.] 10'-3" [3.12M.] 78'-5" [23.90M.] 19'-11" [6.07M.] 19'-8 1 4 " [6.00M.] 78'-5" [23.90M.] 19'-8 1 4 " [6.00M.] 117'-11" [35.94M.] 19'-9 3 4 " [6.04M.] 25'-0 3 4 " [7.64M.] 49'-4" [15.04M.] 29'-7 1 2 " [9.03M.] BAL. BAL. 29'-4" [8.94M.] 50'-5 3 4 " [15.39M.] 31'-3 1 4 " [9.53M.] 27'-1" [8.26M.] UNIT-B UNIT-D UNIT-C UNIT-E UNIT-F UNIT-G UNIT-H UNIT-J (STUDIO - 512sqft) #502 (ADAP.) (1BR - 537 sqft) #501 2BR- 666 sqft) #509 (3 BR - 853 sqft) #503 (1BR - 634 sqft) #505 UNIT-A (2BR- 789sqft) #511 (1BR - 491 sqft) #510 (1BR - 432 sqft) #504 (ADAP.) (1BR - 689 sqft) #506 UNIT-K UNIT-K1 (2 BR - 885sqft) #512 (2 BR 797 sqft) #508 UNIT-C (STUDIO - 512sqft) #513 UNIT-H (ADAP.) (1BR - 689 sqft) #507 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.5 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N FIFTH FLOOR PLAN 1/16" = 1'-0" --- page 33 --- UP DN UP DN BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. BAL. STAIR-B ELEV. LANE NEW PROPERTY LINE EX PROPERTY LINE PROPERTY LINE NEIGHBOURING LOT NEIGHBOURING LOT PROPERTY LINE PROPERTY LINE 54 A AVENUE 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK 9'-10" [3.00M.] SETBACK 1.90m ROAD DEDICATION BAL. A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A BAL. 5'-11" [1.81M.] 19'-8 1 4 " [6.00M.] SETBACK 169'-11 3 4 " [51.81M.] 163'-10 1 2 " [49.95M.] 118'-0" [35.97M.] 78'-5" [23.90M.] 19'-11" [6.07M.] 19'-8 1 4 " [6.00M.] 78'-5" [23.90M.] 19'-8 1 4 " [6.00M.] 117'-11" [35.94M.] 19'-9 3 4 " [6.04M.] 19'-8 1 4 " [6.00M.] 20'-0" [6.10M.] 10'-6 1 2 " [3.22M.] 25'-0 3 4 " [7.64M.] 10'-3" [3.12M.] 25'-0 3 4 " [7.64M.] 49'-4 1 2 " [15.05M.] 29'-7 1 2 " [9.03M.] 29'-4" [8.94M.] 50'-5 3 4 " [15.39M.] 31'-3 1 4 " [9.53M.] 27'-1" [8.26M.] 1.5m WIDE HALLWAY UNIT-B UNIT-D UNIT-C UNIT-E UNIT-F UNIT-G UNIT-H UNIT-J (STUDIO - 512sqft) #602 (ADAP.) (1BR - 537 sqft) #601 2BR- 666 sqft) #609 (3 BR - 853 sqft) #603 (1BR - 634 sqft) #605 UNIT-A (2BR- 789sqft) #611 (1BR - 491 sqft) #610 (1BR - 432 sqft) #604 (ADAP.) (1BR - 689 sqft) #606 UNIT-K UNIT-K1 (2 BR - 885sqft) #612 (2 BR 797 sqft) #608 UNIT-C (STUDIO - 512sqft) #613 UNIT-H (ADAP.) (1BR - 689 sqft) #607 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.6 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N SIXTH FLOOR PLAN 1/16" = 1'-0" --- page 34 --- DN DN INACCESSIBLE ROOF LANE NEW PROPERTY LINE EX PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 54 A AVENUE 19'-8 1 4 " [6.00M.] SETBACK 19'-8 1 4 " [6.00M.] SETBACK STAIR-B 19'-8 1 4 " [6.00M.] SETBACK 9'-10" [3.00M.] SETBACK 169'-11 3 4 " [51.81M.] 118'-0" [35.97M.] ELEV. INACCESSIBLE ROOF INACCESSIBLE ROOF OUTDOOR AMENITY (214.5 SQM) 1.90m ROAD DEDICATION 117'-11" [35.94M.] NEIGHBOURING LOT NEIGHBOURING LOT HIGH ALBEDO ROOF SRI 75+ A A-4.0 A A-4.0 B A-4.0 B A-4.0 C A-4.1 C A-4.1 STAIR-A 19'-8 1 4 " [6.00M.] 20'-0" [6.10M.] 9'-9 3 4 " [2.99M.] 169'-11 3 4 " [51.81M.] 163'-10 1 2 " [49.95M.] 118'-0" [35.97M.] 25'-0 3 4 " [7.64M.] 10'-3" [3.12M.] 78'-5" [23.90M.] 19'-11" [6.07M.] 19'-8 1 4 " [6.00M.] 78'-5" [23.90M.] 19'-8 1 4 " [6.00M.] 117'-11" [35.94M.] 19'-9 3 4 " [6.04M.] 25'-0 3 4 " [7.64M.] 29'-2" [8.89M.] 30'-4" [9.25M.] 50'-7 1 4 " [15.42M.] 31'-2" [9.50M.] 27'-1" [8.26M.] 49'-4 1 4 " [15.04M.] LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-2.7 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 N ROOF TOP 1/16" = 1'-0" --- page 35 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.0 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES 1 PERSPECTIVE VIEW ALONG 54A AVENUE N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N --- page 36 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.1 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1 PERSPECTIVE VIEW ALONG 54A AVENUE (ENTRANCE) --- page 37 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.2 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1 PERSPECTIVE VIEW ALONG SOUTH-WEST CORNER --- page 38 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.3 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1 PERSPECTIVE VIEW ALONG SOUTH-EAST CORNER --- page 39 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.4 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1 PERSPECTIVE VIEW FROM WEST NEIGHBOURING LOT --- page 40 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.5 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1 PERSPECTIVE VIEW FROM NORTH-WEST CORNER --- page 41 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.6 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1 PERSPECTIVE VIEW FROM NORTH-EAST CORNER --- page 42 --- LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.7 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 PERSPECTIVES 1 PERSPECTIVE VIEW FROM NE CORNER (REAR ENTRANCE) N.T.S EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N --- page 43 --- P.L Proposed Building 3m LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.8 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N MATERIAL BOARD 1 3 4 8 7 5 6- Fiber Cement Panelling with Reveal Color to Match: James Hardie_ Gray Slate 1 - Double Glazed Windows Color to Match :Benjamin Moore Black Ink_2127-20 Glass : Clear 7- Fiber Cement Panelling with Reveal Color to Match: James Hardie_ Iron Gray * NOTE: All fiber cement panels trims/recess, reveals, reglets, etc. must be colored matching to the panels they are attached to. 8 - Metal Railing: Color To Match:Benjamin Moore Black Ink_2127-20 Clear Glass 2 6 2 - Aluminium Door & Double Glazed Glass Color to Match : Benjamin Moore Black Ink 2127-20 Glass :Clear 4- James Hardie Siding _Rustic Series : Woodtone Color to Match: Sand Castle Size: 6" Siding 3- Brick Veneer : IXL Building Products ltd. Color: Thin brick - Sienna Ironspot 5- Metal Railing: Color To Match:Benjamin Moore Black Ink_2127-20 SOUTH ELEVATION (ALONG 54 AVE) 8 7 --- page 44 --- Boulevard City S/W 3m Setback Proposed Building Surface Parking Lane P.L EX. P.L P.L 54a Ave. 10.24 10.10 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] THIRD FLOOR LVL SECOND FLOOR LVL MAIN FLOOR LVL FIFTH FLOOR LVL SIXTH FLOOR LVL TOP OF ROOF 11'-10" [3.61M.] 10.23 10.34 P.L EX. P.L P.L Lane Surface Parking Proposed Building 3m Setback City S/W Boulevard 54a Ave. Garbage Enclosure 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] THIRD FLOOR LVL SECOND FLOOR LVL MAIN FLOOR LVL FIFTH FLOOR LVL SIXTH FLOOR LVL TOP OF ROOF 11'-10" [3.61M.] LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.9 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 ELEVATIONS 2 EAST ELEVATION SCALE- 1/16" = 1'-0" EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N 1/16" = 1'-0" 1 WEST ELEVATION SCALE- 1/16" = 1'-0" 2 1 --- page 45 --- 10.20 10.15m 10.10m 10.10m P.L P.L 6m Setback Proposed Building 6m Setback Neighbouring lot 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] 19.90 FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 16.85 THIRD FLOOR LVL 13.80 SECOND FLOOR LVL 10.75 MAIN FLOOR LVL 22.95 FIFTH FLOOR LVL 26.00 SIXTH FLOOR LVL 29.05 TOP OF ROOF 11'-10" [3.61M.] 10.25 10.22 10.27 10.24 P.L P.L 6m Setback Proposed Building 6m Setback Neighbouring lot Garbage Enclosed 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] 19.90 FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 16.85 THIRD FLOOR LVL 13.80 SECOND FLOOR LVL 10.75 MAIN FLOOR LVL 22.95 FIFTH FLOOR LVL 26.00 SIXTH FLOOR LVL 29.05 TOP OF ROOF 11'-10" [3.61M.] LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-3.10 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N ELEVATIONS 1/16" = 1'-0" 2 NORTH ELEVATION SCALE- 1/16" = 1'-0" 1 SOUTH ELEVATION SCALE- 1/16" = 1'-0" 2 1 --- page 46 --- 7'-5 1 4 " [2.27M.] 9'-11" [3.02M.] DETENTION TANK 6.1m WIDE DRIVE AISLE UNIT- B UNIT- A UNIT- J UNIT- B UNIT- A UNIT- J UNIT- B UNIT- A UNIT- J UNIT- B UNIT- A UNIT- J UNIT- B UNIT- A VEST RESIDENTIAL LOBBY P.L. P.L. LVL. 7.14 LVL. 7.42 Neighbouring lot 6m Setback Proposed Building 6m Setback Neighbouring lot LVL. 10.60 LVL. 10.75 LVL. 10.60 2 SC 1 SC 3 SC 8 SC 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] 19.90 FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 16.85 THIRD FLOOR LVL 13.80 SECOND FLOOR LVL 10.75 MAIN FLOOR LVL 22.95 FIFTH FLOOR LVL 26.00 SIXTH FLOOR LVL 29.05 TOP OF ROOF 7.14 PARKADE 1 11'-10" [3.61M.] (POTENTIAL LOCATION) 10.08 10.20 LOCKERS ROOM UNIT- B UNIT- A UNIT- J STAIR-A 8'-7 3 4 " [2.64M.] 9'-5" [2.87M.] 9'-11" [3.02M.] 6.1m WIDE DRIVE AISLE 6.1m WIDE DRIVE AISLE LOCKER'S ROOM LOCKER'S ROOM UNIT- G UNIT- H UNIT- I UNIT- K1 UNIT- J UNIT- G UNIT- H UNIT- I UNIT- K1 UNIT- J UNIT- G UNIT- H UNIT- I UNIT- K1 UNIT- J UNIT- G UNIT- H UNIT- I UNIT- K1 UNIT- J UNIT- G UNIT- H UNIT- I UNIT- K1 UNIT- J INDOOR AMENITY VEST BAL. BAL. BAL. BAL. BAL. P.L. EX. P.L. P.L. LVL. 7.14 54a Ave. Boulevard City S/W 3m Setback Proposed Building Surface Parking 1.9m Road Dedication Lane 27 32 2 SC 39 V7 sc 6.1m WIDE DRIVE AISLE V5 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] 19.90 FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 16.85 THIRD FLOOR LVL 13.80 SECOND FLOOR LVL 10.75 MAIN FLOOR LVL 22.95 FIFTH FLOOR LVL 26.00 SIXTH FLOOR LVL 29.05 TOP OF ROOF 7.14 PARKADE 1 11'-10" [3.61M.] LVL 7.33 10.10 10.21 LVL 10.38 10.73 sc M.F.E 10.75 LVL 7.14 RESIDENTIAL LOBBY UNIT-C2 9'-11 3 4 " [3.04M.] LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-4.0 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 SECTIONS EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N N.T.S 1 SECTION A-A Scale: N.T.S 2 SECTION B-B Scale: N.T.S KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN KEY PLAN A A B B --- page 47 --- 8'-6" [2.59M.] RAMP DN TO PARKADE @14% SLOPE DETENTION TANK (POTENTIAL LOCATION) MECH. ROOM LVL. 7.42 LVL. 7.14 6.1m WIDE DRIVE AISLE P.L. EX.P.L. P.L. LVL. 10.22 LVL 10.22 LVL. 10.72 LVL. 10.44 54a Ave. Boulevard City S/W 3m Setback Proposed Building Surface Parking 1.9m Road Dedication Lane 10'-0" [3.05M.] 10'-0" [3.05M.] 60'-0" [18.29M.] 19.90 FOURTH FLOOR LVL 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 10'-0" [3.05M.] 16.85 THIRD FLOOR LVL 13.80 SECOND FLOOR LVL 10.75 MAIN FLOOR LVL 22.95 FIFTH FLOOR LVL 26.00 SIXTH FLOOR LVL 29.05 TOP OF ROOF 7.14 PARKADE 1 11'-10" [3.61M.] 6.1m WIDE DRIVE AISLE PATIO 10.22 10.08 6'-10 1 2 " [2.10M.] 30 LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-4.1 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 SECTIONS EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N C C 1 SECTION C-C Scale: N.T.S N.T.S --- page 48 --- 11'-6 3 4 " 9'-1" 2'-0 3 4 " 10'-4 1 2 " 12'-6" 22'-10" [6.97m] 22'-8" [6.92m] 10'-9 1 2 " 10'-9 1 2 " 21'-7" [6.58m] 6'-7" 24'-10 1 2 " [7.58m] 3'-3 1 2 " [1.01m] BEDROOM WASH ROOM CLO. W/D KITCHEN LIVING/DINING AREA: 491 sq.ft. BALCONY 6'-2 1 2 " [1.89m] 3'-6 1 2 " [1.08m] 5'-7" [1.70m] 2'-11 1 2 " [0.90m] CLO. STORAGE LOCKER 369 cu.ft. 11'-6 3 4 " 9'-1" 8'-9" 10'-4 1 2 " 9'-8 3 4 " 29'-5" [8.96m] 29'-5" [8.96m] 10'-9 1 2 " 10'-9 1 2 " 21'-7" [6.58m] 6'-7" 24'-10 1 2 " [7.58m] 3'-3 1 2 " [1.01m] BEDROOM WASH ROOM CLO. W/D KITCHEN LIVING/DINING AREA: 535 sq.ft. BALCONY 6'-2 1 2 " [1.89m] 3'-6 1 2 " [1.08m] 5'-7" [1.70m] 2'-11 1 2 " [0.90m] WIC STORAGE LOCKER 369 cu.ft. LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.0 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 1 UNIT TYPE-A 1BR 2 UNIT TYPE-A1 1BR 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan A1 A A --- page 49 --- 33'-10" [10.31m] 12'-3" 2'-4 1 2 " 2'-4 1 2 " 11'-2 1 4 " 28'-2" [8.59m] 5'-8" [1.72m] 9'-11" 17'-2" 27'-1" [8.25m] 9'-11" 9'-7" 2'-1" 5'-4" 26'-11" [8.20m] WASH ROOM PRIMARY BEDROOM CLO. CLO. BEDROOM W/D LIVING/DINING AREA: 789 sq.ft. BALCONY KITCHEN STORAGE LOCKER 436 cu.ft. 10'-8 1 2 " 8'-8 1 2 " 5'-6 1 2 " 7'-6 1 2 " [2.30m] 12'-6 1 2 " 14'-0 1 2 " 5'-11" 32'-6" [9.91m] 32'-6" [9.91m] 15'-9" [4.80m] 2'-9" 4'-0" 9'-0" 15'-9" [4.80m] BEDROOM WASHROOM STORAGE LOCKER CLO. KITCHEN W/D LIVING/DINING AREA: 512 sq.ft. BALCONY 319 cu.ft. LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.1 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 2 UNIT TYPE-C STUDIO 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan C C C C C 1 UNIT TYPE-B 2BR B B B --- page 50 --- 4'-8 1 4 " 9'-3 3 4 " 8'-9" 5'-6 1 4 " 16'-3 1 4 " 14'-0" 5'-7" 35'-10" [10.91m] 35'-9 3 4 " [10.91m] 16'-1 1 2 " [4.91m] 3'-1 1 2 " 3'-7 1 2 " 9'-4 1 2 " 16'-1 1 2 " [4.91m] 7'-6 1 2 " 1'-0" 15'-1 1 2 " BEDROOM WASHROOM STORAGE LOCKER CLO. KITCHEN W/D LIVING/DINING AREA: 573 sq.ft. BALCONY 319 cu.ft. 11'-4" 13'-6" 7'-8" 11'-3" 5'-4 1 2 " 7'-7 1 2 " 8'-3" [2.51m] 24'-3" [7.39m] 32'-6" [9.91m] 9'-6" 9'-7" 19'-1" [5.82m] 10'-2" 2'-11" 6'-0" 19'-1" [5.82m] BEDROOM WASHROOM CLO. KITCHEN W/D LIVING/DINING W.I.C AREA: 537 sq.ft. BALCONY 10'-8 1 2 " 8'-8 1 2 " 5'-6 1 2 " 7'-6 1 2 " 10'-6 1 2 " 13'-11" 4'-3" 28'-9" [8.76m] 32'-6" [9.91m] 3'-9" [1.15m] 15'-9" [4.80m] 2'-11 1 2 " 4'-5" 8'-4 1 2 " 15'-9" [4.80m] BEDROOM WASHROOM STORAGE LOCKER CLO. KITCHEN W/D LIVING/DINING AREA: 501 sq.ft. BALCONY 280 cu.ft. LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.2 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan C2 3 UNIT TYPE-D (ADAPTABLE UNIT) 1BR D D 1 UNIT TYPE-C STUDIO 2 UNIT TYPE-C2 STUDIO C1 --- page 51 --- 9'-11" 10'-4" 9'-11" 27'-2" 33'-5 1 4 " [10.19m] 37'-1" [11.31m] 10'-2 3 4 " 24'-10 3 4 " [7.59m] 5'-4" 8'-0" 11'-6 3 4 " 24'-10 3 4 " [7.59m] 2'-4 1 2 " 2'-4 1 2 " 2'-4 1 2 " 12'-3 1 2 " LIVING/DINING BEDROOM CLO. CLO. KITCHEN WASH ROOM CLO. CLO. W/D BEDROOM PRIMARY BEDROOM AREA: 853 sq.ft. BALCONY 10'-9 3 4 " STORAGE LOCKER 434 cu.ft. 10'-9" 11'-3" 22'-0" [6.71m] 3'-7 3 4 " 9'-0" 9'-4 1 4 " 22'-0" [6.71m] 9'-4" 10'-2" 19'-7" [5.96m] 5'-11" 2'-9" 10'-10 3 4 " 19'-7" [5.96m] LIVING/DINING BEDROOM WASH ROOM CLO. KITCHEN CLO. W/D AREA: 432 sq.ft. BALCONY LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.3 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 1 UNIT TYPE-E 3BR 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan E E 2 UNIT TYPE-F 1BR F F --- page 52 --- 11'-4 1 4 " 10'-3" 12'-9" 34'-4 1 4 " [10.47m] 34'-4 1 4 " [10.47m] 5'-4" 7'-3 1 4 " 12'-3 3 4 " 24'-11" [7.59m] 8'-6 1 2 " 16'-6 1 4 " 25'-1" [7.64m] LIVING/DINING BEDROOM KITCHEN CLO. CLO. WASH ROOM W/D AREA: 634 sq.ft. BALCONY 4'-3 1 2 " 4'-3" 25'-9 3 4 " STORAGE LOCKER 458 cu.ft. 8'-11" 10'-0" 31'-0" [9.45m] 9'-0 1 2 " 9'-3 1 2 " 12'-8" 31'-0" [9.45m] 6'-1 1 2 " 7'-6" 16'-2" [4.93m] 8'-6 1 2 " [2.60m] 12'-8 1 2 " 11'-11 1 2 " 24'-8" [7.52m] LIVING/DINING KITCHEN BEDROOM WASHROOM W.I.C CLO. W/D AREA: 688 sq.ft. BALCONY 2'-6 1 2 " 12'-1" STORAGE LOCKER 505 cu.ft. LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.4 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan 1 UNIT TYPE-G 1BR G G 2 UNIT TYPE-H (ADAPTABLE UNIT) 1BR H H --- page 53 --- 7'-9" 3'-11" 11'-1 1 2 " 9'-6 1 2 " 21'-2 1 2 " [6.46m] 27'-0" [8.23m] 6'-7" 7'-9 1 2 " 8'-0" 3'-6 1 2 " 4'-3" 30'-2" [9.19m] 9'-8" 2'-4 1 2 " 5'-4" 2'-7" 9'-8" 29'-7 1 2 " [9.03m] LIVING/DINING KITCHEN BEDROOM W/D CLO. BEDROOM CLO. CLO. WASH ROOM AREA: 666 sq.ft. BALCONY 4'-9 1 2 " STORAGE LOCKER 286 cu.ft. 6'-3 3 4 " 9'-10" 28'-5 3 4 " [8.68m] 11'-1 1 2 " 31'-6" [9.60m] 10'-6 1 4 " 9'-10 1 4 " 5'-4 3 4 " 13'-3" LIVING/DINING KITCHEN WASH ROOM W.I.C W.I.C ENSUITE BEDROOM PRIMARY BEDROOM CLO. W/D AREA: 885 sq.ft. BALCONY CLO. 6'-5 1 2 " 5'-8 1 4 " 10'-1" 2'-11 1 2 " 31'-6" [9.60m] 3'-9" 3'-4 3 4 " 5'-4 3 4 " 5'-4 1 2 " 10'-6 1 2 " 28'-5 1 2 " [8.67m] STORAGE LOCKER 585 cu.ft. LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.5 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan 1 UNIT TYPE-J 2BR J J K K 2 UNIT TYPE-K 2BR --- page 54 --- 9'-10 3 4 " 29'-6" [8.99m] 10'-2 3 4 " 27'-0" [8.23m] 9'-4 1 2 " 29'-6" [8.99m] 5'-8 1 4 " 27'-0" [8.23m] 8'-6 3 4 " 10'-3 3 4 " 9'-9 3 4 " 5'-8 3 4 " 11'-0 1 2 " 11'-0 1 2 " LIVING/DINING KITCHEN WASH ROOM W.I.C W.I.C ENSUITE BEDROOM PRIMARY BEDROOM CLO. W/D AREA: 797 sq.ft. BALCONY CLO. 5'-4 3 4 " 5'-4 1 2 " 10'-6 1 2 " STORAGE LOCKER 426 cu.ft. LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-5.6 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 UNIT PLANS 3/16" = 1'-0" Main Floor Key Plan Floor 2 Key Plan Floor 3-6 key Plan 1 UNIT TYPE-K1 2BR K1 K1 --- page 55 --- 3 CUBIC Yd CONTAINER 360 Lt TOTE 360 Lt TOTE 360 Lt TOTE 360 Lt TOTE 3 CUBIC Yd CONTAINER FLOOR DRAIN 6'-0" X 1'-6" VENT 8" CONC. BLOCK WALL AS/STRUCTURE LOCKING STEEL ENTRY DOOR c\w ADO FOR ACCESSIBILITY ROOF LINE ABOVE ROOF LINE ABOVE 8'-1" 21'-1" HEAVY DUTY COMMERCIAL GRADE ROLL-UP STEEL DOOR LANE 2% SLOPE 12'-2" 1'-1" 3'-0" 11" 8'-8" 3'-0" 3 CUBIC Yd CONTAINER 2% SLOPE 3 CUBIC Yd CONTAINER 3'-11" 18'-9" STAGING AREA 1'-0" NOTES: 1.ENCLOSURE ARCHITECTURE(MATERIALS,etc.)IS TO CONFORM TO MUNICIPAL BUILDING AND DEVELOPMENT PERMIT REQUIREMENTS(AS REQUIRED). 2. STRUCTURES TO BE CONSTRUCTED IN ACCORDANCE WITH THE BC BUILDING CODE. ENCLOSURES ARE TO BE DESIGNED TO WITHSTAND SNOW LOADING, VEHICULAR DAMAGE, OPERATIONAL DAMAGE, AND BEARS. 3.ROOFS SHOULD BE DESIGNED TO AVOID SNOW SHED IN FRONT OF SERVICE AND ENTRY DOORS. 4. STEEL ENTRY DOOR IS TO BE 36" WIDE (915MM) AND BE EQUIPPED WITH A SELF-CLOSING MECHANISM. DOOR MAY HAVE A ROUND TURNING KNOB COMPLETE WITH A COVERED KEYED KNOB GUARD ON THE EXTERIOR FOR ACCESS AND PANIC HARDWARE ON INTERIOR FOR EGRESS. 5. ADEQUATE MOTION ACTIVATED INTERIOR AND EXTERIOR LIGHTING (IF REQUIRED). P.L EX.P.L CONCRETE ROOF SLOPE DN @5% SLOPE 6'-0" X 1'-6" VENT PAINT MATCH WITH THE BUILDING COLOR PARKADE LVL-1 BELLOW 10'-0" [3.05m] 6.1m WIDE DRIVE AISLE 1.9m Road Dedication GARBAGE AREA Drive Aisle Lane 1'-0" 2'-3" 2'-0" [0.61m] HEAVY DUTY COMMERCIAL GRADE ROLL-UP STEEL DOOR PAINT MATCH WITH THE BUILDING COLOR PMT V1 SC 3'-0"X1'-4" VENT GARBAGE AREA PMT CONCRETE ROOF 10'-0" [3.05m] 7'-0" [2.13m] PARKING EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-6.0 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 KEY PLAN N 2 GARBAGE ENCLOSURE PLAN Scale: 1/4"=1'-0" 1 NORTH ELEVATION Scale: 1/4"=1'-0" 3 WEST ELEVATION Scale: 1/4"=1'-0" 1/4"=1'-0" GARBAGE ENCLOSURE DETAIL --- page 56 --- 8'-0" [2.44m] B SIZE D SIZE 5'-3" [1.60m] 1'-3" [0.38m] 4'-0" [1.22m] 11.05 MAIN FLOOR LVL. 2 1 4 " [0.06m] 8'-0" [2.44m] 2 1 4 " [0.06m] 1'-2" [0.36m] 1'-0" [0.30m] MAIL ROOM 1'-2" [0.36m] 5'-4 1 2 " [1.64m] 6'-6 1 2 " [1.99m] 8'-4 1 2 " [2.56m] A PARCEL LOCKER SITTING 1'-0" [0.30m] 1'-0" [0.30m] 1'-0" [0.30m] 3" [0.08m] LA19_2306 20239,20247 54A Ave, Langley City, BC Sheet No. Project Title Project Address Notes This drawing, as an instrument of service, is the property of the Architect and may not be reproduced without their permission and unless the reproduction carries their name. All design and other information shown on this drawing are for the use on the specified project only and shall not be used otherwise without written permission of the Architect. Written dimension shall have precedence over scaled dimensions. Drawn By Checked By Date Project ID 2023-07-10 Seal Sheet Title Scale Date Description Issues / Revisions Preliminary Application 2023-07-10 MULTI FAMILY DEVELOPMENT MG December 3, 2024 A-6.1 PS 308 - 9639 137A Street, Surrey BC V3T 0M1 1690 West 2nd Avenue, Vancouver, BC V6J 1H4 604-608-0161 | paramorph.com D.P. Submission 2023-12-13 D.P. Submission 2024-06-13 Revisions/Comments 2024-09-06 Revisions/Comments 2024-10-17 Revisions/Comments 2024-11-19 EX PROPERTY LINE NEW PROPERTY LINE NEIGHBOURING LOT 54 A AVENUE LANE NEIGHBOURING LOT KEY PLAN N " D" size [11 UNIT] Approximately 30.5 cm x 30.5 cm. Used for large volume receivers in business applications as well as optional parcel compartments. " B" size [84 UNIT] Personal compartments for residential and small business applications. These are minimum size requirements, regardless of front-loading or rear-loading lockbox assemblies. All with 35 cm of minimum (min.) depth.(As/Canada Post) 1 MAIL ROOM PLAN Scale: 3/8" = 1'-0" 2 MAIL ROOM ELEVATION -A Scale: 3/8" = 1'-0" MAILBOX DETAIL 3/8" = 1'-0" --- page 57 --- --- page 58 --- --- page 59 --- --- page 60 --- --- page 61 --- --- page 62 --- --- page 63 --- --- page 64 --- --- page 65 --- --- page 66 --- --- page 67 --- --- page 68 --- --- page 69 --- --- page 70 ---